ST HF PLO

PRODUCT MODEL:

Slow Transition HF PLO

DESCRIPTION:

The Slow Transition PLO crystal oscillator provides smooth frequency transition on loss and reacquisition of the external reference. This innovative design features a low PLL BW (≤0.1 Hz), guaranteed maximum slew rate, automatic aging correction and frequency holdover upon loss of reference, while maintaining excellent close-in noise of -145dBc at 10Hz.

  • Smooth Frequency Transition on Loss/Reacquisition of Ext Ref (≤60 ppb/second)
  • Frequency Calibration and Aging Correction Function
  • To -145 dBc/Hz @ 10 Hz offset
  • PLL LBW: ≤ 0.1 Hz
  • Low G-Sensitivity to ≤ 3E-10/g
  • Package: 2.5 x 2.5 x 0.6 in
  • Vibration Isolated Option
  • Up/Down Converters
  • GPS Receivers
  • System Synchronization
  • Test Equipment
  • Radar Systems

View the Plot

Features

The Slow Transition PLO crystal oscillator provides smooth frequency transition on loss and reacquisition of the external reference. This innovative design features a low PLL BW (≤0.1 Hz), guaranteed maximum slew rate, automatic aging correction and frequency holdover upon loss of reference, while maintaining excellent close-in noise of -145dBc at 10Hz.

  • Smooth Frequency Transition on Loss/Reacquisition of Ext Ref (≤60 ppb/second)
  • Frequency Calibration and Aging Correction Function
  • To -145 dBc/Hz @ 10 Hz offset
  • PLL LBW: ≤ 0.1 Hz
  • Low G-Sensitivity to ≤ 3E-10/g
  • Package: 2.5 x 2.5 x 0.6 in
  • Vibration Isolated Option
  • Up/Down Converters
  • GPS Receivers
  • System Synchronization
  • Test Equipment
  • Radar Systems

Applications

The Slow Transition PLO crystal oscillator provides smooth frequency transition on loss and reacquisition of the external reference. This innovative design features a low PLL BW (≤0.1 Hz), guaranteed maximum slew rate, automatic aging correction and frequency holdover upon loss of reference, while maintaining excellent close-in noise of -145dBc at 10Hz.

  • Smooth Frequency Transition on Loss/Reacquisition of Ext Ref (≤60 ppb/second)
  • Frequency Calibration and Aging Correction Function
  • To -145 dBc/Hz @ 10 Hz offset
  • PLL LBW: ≤ 0.1 Hz
  • Low G-Sensitivity to ≤ 3E-10/g
  • Package: 2.5 x 2.5 x 0.6 in
  • Vibration Isolated Option
  • Up/Down Converters
  • GPS Receivers
  • System Synchronization
  • Test Equipment
  • Radar Systems

Specifications

None Provided

Mechanical Drawing

ST HF PLO

Mechanical Drawing Detail for Slow Transition HF PLO

ST HF PLO

View Product Solutions